Having trouble with your Festool power tool? Well, we're here to help you. Before posting to the forum, give us a chance to diagnose and resolve your issue. In the U.S. and Canada, call us toll-free at 888-337-8600 on Monday-Friday between 8a-5p EST or contact us via email at service@festoolusa.com. For other countries, please visit http://www.festool.com for contact information for your local Festool service department.

Author Topic: CT 15 Max Connected Load  (Read 720 times)

0 Members and 1 Guest are viewing this topic.

Offline Eric J

  • Posts: 27
CT 15 Max Connected Load
« on: May 15, 2020, 09:20 AM »
Hi everyone,

I picked up a CT 15 dust extractor last weekend. I intend to use it for dust collection on my TS 55 and as a general shop vac. I thumbed through the manual this morning and discovered that the maximum connected load through the built-in electrical outlet is just 240W (2A @ 120V).

314445-0

Obviously this is not enough to support a TS 55. It looks like the other Festool CT dust extractors are rated for 1200W load at the outlet. Is the CT 15 indeed limited to 240W or is it actually 1200W like the other CT models? I made a few short plunge cuts with my TS 55 plugged in, but haven't tried anything that would be thermally taxing yet.

Thanks,
Eric

Festool USA does not pre-approve the contents of this website nor endorse the application or use of any Festool product in any way other than in the manner described in the Festool Instruction Manual. To reduce the risk of serious injury and/or damage to your Festool product, always read, understand and follow all warnings and instructions in your Festool product's Instruction Manual. Although Festool strives for accuracy in the website material, the website may contain inaccuracies. Festool makes no representations about the accuracy, reliability, completeness or timeliness of the material on this website or about the results to be obtained from using the website. Festool and its affiliates cannot be responsible for improper postings or your reliance on the website's material. Your use of any material contained on this website is entirely at your own risk. The content contained on this site is provided for informational purposes only and does not constitute professional advice.


Offline ctvader

  • Posts: 73
Re: CT 15 Max Connected Load
« Reply #1 on: May 15, 2020, 10:36 AM »
I’ve used it with a TS 55, DW 716 miter saw without issue.  Maybe someone from Festool can opine

Offline xedos

  • Posts: 472
Re: CT 15 Max Connected Load
« Reply #2 on: May 15, 2020, 04:54 PM »
Short answer - don't worry about it.

Long answer:   Festool's vacs don't support most for their tools connected to the receptacle if you're looking at it from a 1 to 1 watt/amp rating.  But all their tools are designed to plug into their vacs.

Festool's "other" vac's outlets aren't rated for 1200w connected either.  They are rated at 3.7amp or 440w roughly with a total connected load of 1440watts.   Slightly more than the ct15.   That 440w exceeds all their saws and routers, plus the large Domino and the Planer.

Festool's official response to your question:

https://www.festoolownersgroup.com/ask-festool/amp-rating-on-festool-dust-extractor-outlet/

you might want to read:
https://festoolownersgroup.com/index.php?pretty;board=ask-festool;topic=dust-extractors.msg389635#msg389635




Offline CeeJay

  • Posts: 293
Re: CT 15 Max Connected Load
« Reply #3 on: May 15, 2020, 07:30 PM »
I believe the CT15 and CT Midi have the same motor and electrical.

I use my Midi at a mitre station with a 1500W Makita saw. It hasn’t tripped the Midi yet - I’ve cut 50mm by 300mm hardwood boards with it.

Note that I’m in Australia so running off 240V however.


Sent from my iPhone using Tapatalk

Offline Eric J

  • Posts: 27
Re: CT 15 Max Connected Load
« Reply #4 on: May 16, 2020, 02:36 PM »
Thank you for the responses everyone. It sounds like I can run my TS 55 from the vac without issue. I ended up calling Festool support and received an answer similar to the post that xedos linked to, which was "the CT dust extractors are compatible with all of our tools".

I would love to know where the 240W number came from. Perhaps this is the highest load they can claim without additional certification or testing (which could be country or region specific).

Offline xedos

  • Posts: 472
Re: CT 15 Max Connected Load
« Reply #5 on: May 16, 2020, 10:58 PM »
It's how many rated watts the power cord will support once the turbine draw is subtracted out.  Or, at least that's my reading of what's going on.

Like I said , don't worry about it. 




.............unless you buy a Kapex.